Steel grade |
Механические свойства, не менее |
|||
Yield strength , N/mm |
Tensile strength , N/mm |
Relative elongation , % |
Contraction , % |
|
08 |
196 |
320 |
33 |
60 |
10 |
205 |
330 |
31 |
55 |
15 |
225 |
370 |
27 |
55 |
20 |
245 |
410 |
25 |
55 |
25 |
275 |
450 |
23 |
50 |
30 |
295 |
490 |
21 |
50 |
35 |
315 |
530 |
20 |
45 |
40 |
335 |
570 |
19 |
45 |
45 |
355 |
600 |
16 |
40 |
Note - As agreed between the manufacturer and the customer for steel from steel grades 25, 30, 35, 40, allowed reduction of tensile strength of 20 N/mm, compared with the standards set out in the table, while improving the rules elongation of 2% (abs ).
In bundles, weight 5 tons max., with banding by wire rod 6,5 mm in 4 places min. equally distributed over bundle. Each bundle is provided with 2 steel straps for multiple lifting.
Ultrasonic inspection of surface and internal defects consists of two automated units of ultrasonic continuity inspection of long products "Volna -7 -03" and "Volna-7-04". The minimum depth of detected surface defects is 0.3 mm. Taking into account the specifics of the installation the bar has untested areas - 150 mm at the beginning of the bar and 100 mm at the end. The unit provides control of internal defects according to norms and standards GOST 22120-75, DIN EN 10228-3, DIN EN 10308, SEP 1921, SEP 1920.
The laboratories conducting physic, mechanical, chemical and metallographic tests work in order to control technological production processes and quality of finished steel products. The Central Works Laboratories are accredited for technical competence in accordance with the requirements of the national standard STB/ISO MEC 17025 and DIN EN ISO 17025:2005.
To monitor production processes and evaluate the quality of finished products, there are laboratories that conduct physical, mechanical, chemical and metallographic tests. The CPL laboratories are accredited for technical competence in the main activities in accordance with the requirements of the national standard STB / ISO IEC 17025 and the standard DIN EN ISO 17025:2005.